Research Article
Study on Autogenous Heat Technology of Offshore Oilfield: Experiment Research, Process Design, and Application
Table 4
The effect of catalyst concentration on heat generation rate of system.
| Catalyst concentration: 0.5% HCl | Catalyst concentration: 1.0% HCl | Catalyst concentration: 1.5% HCl | Time (min) | Temperature (°C) | Time (min) | Temperature (°C) | Time (min) | Temperature (°C) | 0 | 25 (indoor temperature) | 0 | 25 (indoor temperature) | 0 | 25 (indoor temperature) |
| 5 | 28 | 5 | 29 | 5 | 34 | 10 | 31 | 10 | 32 | 10 | 41 | 15 | 33 | 15 | 34 | 15 | 45 | 20 | 37 | 20 | 40 | 20 | 50 | 25 | 40 | 25 | 42 | 25 | 52 | 30 | 43 | 30 | 46 | 30 | 52 | 35 | 45 | 35 | 48 | 35 | 51 | 40 | 46 | 40 | 52 | 40 | 50 | 45 | 47 | 45 | 52 | 45 | 49 | 50 | 48 | 50 | 50 | 50 | 49 | 55 | 51 | 55 | 49 | 55 | 48 | 60 | 50 | 60 | 49 | 60 | 47 |
|
|
Concentration of system: 100 mL 2.0 mol/L NaNO2 solution+100 mL 2.0 mol/L NH4Cl solution.
|