Research Article

Mechanical Response of Castlegate Sandstone under Hydrostatic Cyclic Loading

Table 2

Testing conditions for each hydrostatic loading test. Tests with multiple pressure conditions indicate maximum and minimum pressure of each cycle.  = confining pressure;  = pore pressure;  = effective pressure during cycles;  = effective pressure during permeability tests. When two values of , , , or are listed, this represents the maximum and minimum pressure of each cycle.

Sample number (MPa) (MPa) (MPa) (MPa)Cycle time (hours)# of cyclesDuration (days)

CG_00120.6810.34 & 6.8910.34 & 13.790.55852
CG_00320.6810.34 & 6.8910.34 & 13.790.5582810
CG_00420.6810.34 & 6.8910.34 & 13.7910.17 & 6.7284416
CG_00520.6811.03 & 6.209.65 & 14.4810.89 & 6.0786023
CG_00620.6811.03 & 6.209.65 & 14.4810.76 & 5.93416832
CG_00714.82 & 100.359.65 & 14.4714.48 & 9.65411722
CG_00920.6810.3410.3410.2731
CG_01020.6810.34 & 6.2010.34 & 14.4810.34227433