Research Article

Experimental and Numerical Studies on Flowing Properties of Grouting Mortar Based on the Modified MPS Method

Table 2

Measured data of minislump test.

No
(kg/m3)

(Pa·s)

(Pa)
Flow
(mm)

121332.1422.62451.23
221565.0035.181951.57
321402.8226.752261.32

Flow value of minislump test in 5 s (flow pattern of mortar was recorded by the camera during the test).