Research Article
Hydrogeochemical Characteristics and Genesis of the Chazi Geothermal Field Area in Tibet
Table 10
Calculation of underground hot water circulation depth in in the study area.
| Field number | Sampling point elevation/m | Reservoir temperature/°C | Cycle depth/m |
| DR28 | 5054 | 202.1 | 1335 | DR32 | 4262 | 237.7 | 1572 | DR36 | 4886 | 170 | 1121 | DR37 | 5259 | 212 | 1401 | DR40 | 4923 | 160 | 1054 | DR42 | 4382 | 109.4 | 716.4 | DR44 | 4279 | 183.6 | 1212 | DR45 | 4157 | 163 | 1074 | DR47 | 4173 | 144 | 947.1 | DR48 | 4170 | 148 | 973.8 | XZDR9 | 5030 | 185.4 | 1223 | XZDR11 | 4377 | 102 | 667 | XZDR15 | 4733 | 236 | 1561 | CKLSQ | 4839 | 216.5 | 1431 |
|
|