Research Article
Research and Application of a Proppant Transport Experimental Device for Complex Fractures in the Unconventional Reservoir
Table 1
Functional parameters of the proppant transport characteristic complex fracture experimental device.
| Item | Parameter value |
| Unit size of complex fracture device | 600 mm600 mm600 mm | The length and number of main fractures | 600 mm, 1 fracture | The length and number of second fractures | 600 mm, 3 fractures | The length and number of third fractures | 600 mm, 3 fractures | Horizontal fractures | 600 mm, 3 fractures | Fracture height | 150~600 mm | Fracture width | 1~10 mm | Fracture nodes | 27 | Maximum displacement | 200 L/min | Pressure resistance | 1.2 MPa | Suitable proppant types | Various proppant particles of 20~140 mesh | Suitable liquid type | Slickwater, linear gel |
|
|