Research Article

Study on Spontaneous Combustion Law and Prevention Technology of Abandoned Coal in Goaf of Coal Mine

Table 5

Comparison of ignition activation energy between coal samples without and with 4% MgCl2 inhibitor.

Coal sample numberNo blocking agent coalAfter adding inhibitor coalChange in activation energy

No. 1 (reference)122.620.947295122.560.947112-0.06
No. 2 (reference)118.570.995854169.340.94772850.77
No. 3 (reference)117.190.980744155.030.94970337.13
No. 5 (layer 15#)140.570.994579150.680.99234910.11
No. 6134.860.992412168.120.97098933.26
No. 8141.800.992549167.430.94605425.63
No. 9132.340.993876128.630.994922-3.71