Research Article
Study on Spontaneous Combustion Law and Prevention Technology of Abandoned Coal in Goaf of Coal Mine
Table 6
Comparison of ignition activation energy between coal samples without inhibitor and with 15% MgCl2 inhibitor.
| Coal sample | No blocking agent coal | After adding inhibitor coal | Change in activation energy | | | | | |
| No. 1 (reference) | 122.62 | 0.947295 | 152.71 | 0.966805 | 30.09 | No. 2 (reference) | 118.57 | 0.995854 | 194.32 | 0.969737 | 75.75 | No. 3 (reference) | 117.19 | 0.980744 | 209.41 | 0.970496 | 92.22 | No. 5 (15# layer) | 140.57 | 0.994579 | 178.64 | 0.975889 | 38.07 | No. 6 | 134.86 | 0.992412 | 188.52 | 0.961331 | 53.66 | No. 8 | 141.80 | 0.992549 | 196.24 | 0.943866 | 54.44 | No. 9 | 132.34 | 0.993876 | 184.04 | 0.974814 | 51.7 |
|
|