Research Article

Study on Spontaneous Combustion Law and Prevention Technology of Abandoned Coal in Goaf of Coal Mine

Table 6

Comparison of ignition activation energy between coal samples without inhibitor and with 15% MgCl2 inhibitor.

Coal sampleNo blocking agent coalAfter adding inhibitor coalChange in activation energy

No. 1 (reference)122.620.947295152.710.96680530.09
No. 2 (reference)118.570.995854194.320.96973775.75
No. 3 (reference)117.190.980744209.410.97049692.22
No. 5 (15# layer)140.570.994579178.640.97588938.07
No. 6134.860.992412188.520.96133153.66
No. 8141.800.992549196.240.94386654.44
No. 9132.340.993876184.040.97481451.7