Swallowing in Parkinson Patients versus Healthy Controls: Reliability of Measurements in Videofluoroscopy

Table 3

(a) Reliability of the temporal variables (quantitative assessment), intraclass correlation coefficients (ICC)a. (b) Reliability of the spatial-temporal variables (hyoid motion), ICCa. (c) Reliability of the visuoperceptual variables (qualitative assessment), Cohen’s Kappa.
(a)

Temporal variableIntrarater test-retest reliability (ICC)Interrater reliability
(ICC)
Rater 1Rater 2

GPJ opening
GPJ closure0.40.8
GPJ duration0.40.8
VPJ closure0.60.80.7
VPJ opening1.01.00.7
VPJ duration0.91.00.7
LV closure0.90.90.9
LV opening0.90.61.0
LV duration1.00.70.9
UES opening0.40.5
UES closure0.60.80.8
UES duration0.70.8−0.1
GPJo_LVc0.90.90.9
GPJo_UESo0.40.9
GPJo_UESc0.60.8−0.02
Aspiration or penetration

aSingle measures ICC, Cronbach’s alpha >0.65.
(b)

Spatial-temporal variableIntrarater test-retest reliability (ICC)Interrater reliability
(ICC)
Rater 1Rater 2

Maximum horizontal (anterior) hyoid motion.0.90.6
Maximum vertical hyoid motion.0.80.90.8
Duration between initiation of swallow and moment of maximum horizontal (anterior) hyoid motion.0.90.90.9
Duration between initiation of swallow and moment of maximum vertical hyoid motion.0.60.70.9

aSingle measures ICC, Cronbach’s alpha >0.65.
(c)

Visuoperceptual variableIntrarater test-retest reliabilityInterrater reliability
Cohen’s KappaCohen’s Kappa
Rater 1Rater 2Rater 1-2

Preswallow anterior spill
Preswallow posterior spill1.01.0
Lingual pumping1.01.00.6
Swallow hesitancy1.0
Piecemeal deglutition1.01.00.9
Delayed initiation pharyngeal reflex0.81.00.3
Postswallow oral residue0.60.7
Postswallow vallecular pooling0.90.90.6
Postswallow pyriform sinus pooling0.81.00.6
Penetration aspiration [20]1.0