Clinical Study

A Multicenter Randomized Controlled Trial of Malignant Gastric Outlet Obstruction: Tailored Partially Covered Stents (Placed Fluoroscopically) versus Standard Uncovered Stents (Placed Endoscopically)

Table 3

Efficacy and complications.

GOO tailored groupControl groupP value

Technical success96.9%96.9%>0.05
Clinical success93.8%93.5%>0.05
GOOSS change 3.2 ± 0.53.1 ± 0.4>0.05
Ingrowth + overgrowth17<0.05
Migration20>0.05
Adverse events
 Bleeding112<0.05
 Abdominal pain131<0.05
 Food impaction11>0.05
Reintervention rate9.4%22.6%<0.05
Survival (d)231 ± 23212 ± 22>0.05

GOOSS, gastric outlet obstruction score.