Research Article

Preliminary Experience Using Full-Spectrum Endoscopy for Colorectal Cancer Screening: Matched Case Controlled Study

Table 3

Outcomes of endoscopists’ evaluations on the usability of FUSE.

QuestionsEvaluationsComparison to SC

Scope insertion
 Operation of angles2.41.2
 Release of looping21
 Retroflection in rectum2.41.8
Observation
 Field of view4.45
 Brightness2.41.4
 Resolution1.81
 Chromoendoscopy1.81
 Differential magnification function1.81
 Digital diagnosis of neoplastic or nonneoplastic1.81
 Diagnostic ability of invasion depth1.41
Appropriate candidate
 Screening3.63.0
 Polyp surveillance3.63.0
 Detailed work up of early cancer or advanced neoplasia1.41
 Scheduled polypectomy/EMR2.01

SC, standard endoscopy; EMR, endoscopic mucosal resection.