Infectious Diseases in Obstetrics and Gynecology

Infectious Diseases in Obstetrics and Gynecology / 2005 / Article

Open Access

Volume 13 |Article ID 942408 | https://doi.org/10.1080/10647440500068248

A. M. Caliendo, J. A. Jordan, A. M. Green, J. Ingersoll, R. J. Diclemente, G. M. Wingood, "Real-Time PCR Improves Detection of Trichomonas vaginalis Infection Compared With Culture Using Self-Collected Vaginal swabs", Infectious Diseases in Obstetrics and Gynecology, vol. 13, Article ID 942408, 6 pages, 2005. https://doi.org/10.1080/10647440500068248

Real-Time PCR Improves Detection of Trichomonas vaginalis Infection Compared With Culture Using Self-Collected Vaginal swabs

Received02 Jul 2004
Accepted01 Dec 2004

Abstract

Objective. To compare a real-time polymerase chain reaction (PCR) assay with broth culture for the detection of Trichomonas vaginalis using self-collected vaginal swabs.Methods. Self-collected vaginal swabs were obtained from adolescent and young adult African-American women participating in HIV-1 prevention programs. T. vaginalis culture was performed using the InPouch TV System. Samples for the real-time PCR assay were collected using the BDProbeTec ET Culturette Direct Dry Swab system and tested in a laboratory-developed assay which targeted a repeated sequence of the genome. Discrepant samples that were culture negative and positive in the real-time PCR assay were tested in a confirmatory PCR which targeted a different region of the T. vaginalis genome, the18S ribosomal DNA gene.Results. Of the 524 specimens tested by both culture and real-time PCR, 36 were culture positive and 54 were positive in the real-time PCR assay; 16 of the 18 discrepant specimens were also positive in the confirmatory PCR assay. Using a modified gold standard of positive by culture or positive in both PCR assays, the sensitivity of the real-time PCR assay was 100% and the specificity was 99.6%, whereas culture had a sensitivity of 69.2% and a specificity of 100%.Conclusions. The real-time PCR assay was sensitive and specific for the detection of T. vaginalis DNA from self-collected vaginal swab specimens. The ability to use the BDProbeTec dry swab system for the real-time PCR testing allowed for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and T. vaginalis from a single specimen.

Copyright © 2005 Hindawi Publishing Corporation. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


More related articles

 PDF Download Citation Citation
 Order printed copiesOrder
Views225
Downloads1293
Citations

Related articles

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.