Research Article

An UPLC-MS/MS Method for Determination of Osimertinib in Rat Plasma: Application to Investigating the Effect of Ginsenoside Rg3 on the Pharmacokinetics of Osimertinib

Table 2

Calibration standards for osimertinib in rat plasma (linear weighted 1/x2, n = 6).

AnalytesItemNominal standards concentrations (ng/mL)QCs (ng/mL)R2
S1 (1)S2 (5)S3 (20)S4 (50)S5 (100)S6 (200)S7 (300)S8 (400)L (3)M (30)H (350)

OsimertinibMean0.984.8520.6148.8293.82218.05293.07405.602.9631.29361.650.9972
RSD (%)5.616.069.683.395.956.840.793.658.481.714.750.12
RE (%)−2.31−3.013.05−2.36−6.189.02−2.311.27−1.274.283.33