Research Article

Exploiting of Green Synthesized Metal Oxide Nanoparticles in the Potentiometric Determination of Metformin Hydrochloride in Pharmaceutical Products

Table 3

Selectivity coefficient ( MTF+) of conventional MTF-PT and MTF-PT-Al2O3-modified and MTF-PT-NiO-modified sensors using 1.0 × 10−3 M of MTF solution.

Interferences MTF-PT MTF-PT-Al2O3 MTF-PT-NiO

Na+1.3 × 10−31.4 × 10−49.3 × 10−3
Fe3+2.5 × 10−31.6 × 10−35.1 × 10−3
Cr3+5.0 × 10−35.1 × 10−31.9 × 10−3
Ag+3.2 × 10−32.2 × 10−41.7 × 10−3
Ca2+3.8 × 10−35.7 × 10−33.9 × 10−3
K+7.9 × 10−31.9 × 10−41.6 × 10−4
Mg2+1.1 × 10−34.5 × 10−43.2 × 10−4
Co2+1.4 × 10−32.7 × 10−31.0 × 10−3
Serine1.3 × 10−35.5 × 10−35.0 × 10−4
Glycine2.1 × 10−31.3 × 10−41.6 × 10−3
Starch1.9 × 10−32.3 × 10−41.0 × 10−3
Guanidine1.1 × 10−39.2 × 10−48.2 × 10−4
Cycloguanil2.3 × 10−31.8 × 10−49.3 × 10−4
Synthalin5.6 × 10−35.9 × 10−46.5 × 10−4
Galegine4.2 × 10−33.6 × 10−47.4 × 10−4