Research Article
Active Control Optimization for Minimizing the Dynamic Response of Functionally Graded Plate
Table 1
Comparison of
,
,
, and
of simply supported square Al/ZrO
2 FG plates with
.
| | | | | | | | |
| 1 | 5 | 0.0312 | 0.0295 | 0.1391 | 0.1401 | 5.5 | 0.7 | 10 | 3.1358 | 3.0909 | 8.1959 | 8.2149 | 1.4 | 0.2 | 15 | 43.401 | 43.133 | 103.64 | 103.79 | 0.61 | 0.1 | 20 | 247.45 | 246.62 | 662.64 | 663.59 | 0.33 | 0.1 |
| 4 | 5 | 0.0344 | 0.0286 | 0.1062 | 0.1072 | 16.8 | 0.9 | 10 | 3.0272 | 2.8914 | 6.1625 | 6.1720 | 4.5 | 0.2 | 15 | 39.992 | 39.259 | 78.319 | 78.362 | 1.8 | 0.05 | 20 | 221.95 | 219.87 | 499.76 | 500.30 | 0.9 | 0.1 |