Research Article

Experimental Design Validation of Tilting Calibration Mechanism by Using Shape Memory Alloy Spring Actuator

Table 3

Summary of qualification test specifications.
(a) Shock test

Frequency (Hz)SRS (g)

10020
15001000
100001000

(b) Sine Burst Test

Amplitude (g)Sweep

40Ramp-up/ramp-down: 7 cycles

(c) Random Vibration Test

Frequency (Hz)PSD (g2/Hz)Overall grmsDuration

200.00512.44 g60 sec
500.150
8000.150
20000.005