Research Article

Structural Damage Detection Using Nonlinear Vibrations

Table 8

D2, excitation far from the damage, localization indexes.

IndexNode 12Point Point

, min (Hz)7.877.867.79
, max (Hz)8.758.818.93
, range (Hz)0.880.951.14