Research Article
Algorithm Used to Detect Weak Signals Covered by Noise in PIND
Table 1
The cross-correlation coefficient was received by averaging 100 tests.
| No. | Package types | Particle | | Result |
| 1 | 1/5 crystal cover | 0.01 mg tin grain | 0.0993 | Nonexistent | 2 | 1/5 crystal cover | 0.01 mg tin grain | 0.2952 | Nonexistent | 3 | 1/5 crystal cover | 0.01 mg tin grain | 0.6410 | Existent | 4 | 1/5 crystal cover | 0.01 mg tin grain | 0.5545 | Existent | 5 | 1/2 crystal cover | 0.01 mg tin grain | 0.6716 | Existent | 6 | 1/2 crystal cover | 0.01 mg tin grain | 0.4590 | Existent | 7 | 1/2 crystal cover | 0.01 mg tin grain | 0.0250 | Nonexistent | 8 | TO-5 | 0.01 mg tin grain | 0.5944 | Existent | 9 | TO-5 | 0.01 mg tin grain | 0.6538 | Existent | 10 | TO-5 | 0.01 mg tin grain | 0.4751 | Existent | 11 | TO-3 | 0.01 mg tin grain | 0.5304 | Existent | 12 | TO-3 | 0.01 mg tin grain | 0.5202 | Existent | 13 | TO-3 | 0.01 mg tin grain | 0.2746 | Nonexistent | 14 | TO-3 | 0.01 mg tin grain | 0.4588 | Existent |
|
|