Research Article

Computational Investigation of Flow Control Methods in the Impeller Rear Cavity

Table 2

The values of parameters.

LocationConditions
Inlet1Total pressure:
Total temperature:
Inlet2Mass flow rate,
OutletMass flow rate, : 25.8~253 (g/s)
WallsAdiabatic and no slip

ParametersRange
Rotational speed of rotating wall, 5000~30000 (rpm)
0~0.8
Reφ
0.028~0.280