Research Article

Performance Enhancement of Spaceborne Cooler Passive Launch and On-Orbit Vibration Isolation System

Table 6

Summary of microvibration measurement test results.

ParameterRigidPLOVIS-IPLOVIS-II
0 g1 g0 g1 g

Axis
Peak value (N)0.211.110.480.0030.0340.0040.041.080.20.0040.040.0030.130.480.10
RMS value (Nrms)0.160.750.380.0450.0440.0130.040.850.170.060.020.0250.180.260.067