Research Article
Experimental Validation of a Highly Damped Deployable Solar Panel Module with a Pogo Pin-Based Burn Wire Triggering Release Mechanism
Table 4
Summary of the qualification-level launch vibration test specifications.
(a) |
| Sinusoidal vibration test [35] | Level | Frequency (Hz) | Amplitude (g) | Sweep rate (oct/min) |
| 0 dB (full level) | 5 | 1.3 | 2 | 8 | 2.5 | 100 | 2.5 |
|
|
(b) |
| Random vibration test [36] | Level | Frequency (Hz) | Amplitude (g2/Hz) | Test duration (s) | RMS acceleration (Grms) |
| 0 dB (full level) | 20 | 0.026 | 120 | 14.10 | 50 | 0.16 | 800 | 0.16 | 2000 | 0.026 |
|
|