The operating conditions that vary the flow rate of GH2 for the simulation.

Group12345

Flow rate of LOX (g/s)134134134134134
Flow rate of GH2 (g/s)130143161183212
LOX/GH2 mixing ratio1.030.930.830.730.63
Excess oxygen coefficient0.1280.1160.1040.0910.078