Research Article

Anticipated Impact of Hand-Hold Position on the Electromagnetic Interaction of Different Antenna Types/Positions and a Human in Cellular Communications

Table 9

Pooled statistics of peak 1 and 10 g SAR in tissues, radiated power, absorbed power in tissues, dielectric loss, and power budget error for the handset models in hand closed to HR-EFH at different positions operating at 1800 MHz.

Handset modelFrequency/1800 MHz
A1A2B1B2

Hand positionhand1hand2hand1hand2hand1hand2hand1hand2

Antenna input power (mW)125125125125125125125125

Cheek-position in head (W/kg)1.480.851.161.102.671.810.841.49
in head (W/kg)0.660.410.670.551.740.850.510.90
in hand (W/kg)1.283.871.212.010.841.821.651.06
Radiated power (mW)21.09.5536.224.227.915.326.917.3
Absorbed power in head (mW)53.736.245.738.961.744.627.847.7
Absorption rate in head (%)43.029.036.631.249.435.722.338.2
Absorbed power in hand (mW)36.663.931.150.024.358.260.847.0
Dielectric loss (mW)13.412.811.811.410.95.309.3012.3
Power budget error (%)0.182.000.160.330.101.270.120.58

Tilt-position in head (W/kg)1.540.890.931.062.461.660.420.77
in head (W/kg)0.600.350.530.491.100.720.260.45
in hand (W/kg)1.253.801.602.241.122.171.941.36
Radiated power (mW)23.611.035.722.929.218.331.327.2
Absorbed power in head (mW)50.535.742.436.152.237.917.426.8
Absorption rate in head (%)40.428.634.028.941.830.413.921.4
Absorbed power in hand (mW)37.063.134.253.629.760.365.158.0
Dielectric loss (mW)13.212.712.011.413.66.4610.612.8
Power budget error (%)0.441.960.540.740.211.620.450.17