Research Article

A Novel Cellular Handset Design for an Enhanced Antenna Performance and a Reduced SAR in the Human Head

Table 5

The computed averaged peak-SAR (over 1g and 10g) and power absorption in tissues, radiated power, total loss, total isotropic sensitivity, and computation error for both handset models in hand close to head at different positions and at 900 MHz.

900 MHz-Cheek900 MHz-Tilt
SAMHR-EFH (Adult)SAMHR-EFH (Adult)
Handset modelModel no. 1 Model no. 2 Model no. 1Model no. 2Model no. 1Model no. 2Model no. 1Model no. 2

Input power (mW) 600 600 600 600 600 600 600 600
Peak-SAR1g(W/Kg) in head 4.23 3.34 2.99 2.72 1.86 1.34 4.17 1.09
Peak-SAR10g(W/Kg) in head 3.02 2.38 2.55 2.27 1.29 0.98 1.40 0.92
Peak-SAR1g(W/Kg) in hand 1.44 2.70 1.69 2.93 2.02 3.54 2.18 3.57
Peak-SAR10g(W/Kg) in hand 0.82 1.25 0.89 1.31 1.18 1.65 1.19 1.65
Radiated power (mW) 42.60 69.00 74.00 103.50 127.20 110.10 147.00 152.00
Absorbed power in head (mW) 335.20 241.40 312.00 218.50 206.80 126.60 206.00 122.00
Absorption rate in head (%) 55.87 40.23 52.00 36.42 34.47 21.10 34.33 20.33
Absorbed power in hand (mW) 92.27 161.50 94.30 167.90 133.20 224.80 130.00 207.00
Total loss (mW) 103.26 107.20 109.00 99.83 106.20 115.50 108.70 110.00
Total isotropic sensitivity (dBm)
Computation error (%) 4.4 3.5 1.8 1.7 4.8 2.9 0.8 1.6