Research Article

Dual-Feed Small-Size Penta-Band PIFA for LTE/WWAN Mobile Handset Applications

Table 1

Simulated SAR values for 1 g tissues.

Frequency (MHz)900925175019502350

1 g SAR (W/Kg)
 Head only1.321.210.680.560.45
 Hand only1.351.180.750.640.52
 Head and hand1.411.250.720.650.57
Return loss (dB)
 Head only8.910.56.610.88.7
 Hand only12.111.36.811.512.5
 Head and hand12.511.17.117.213.6