Abstract

We define and calculate sensitivity for several actual and simulated probes. Probe sensitivity can have a significant impact on the measurement uncertainty associated with probe deconvolution in near-field spherical-scanning, antenna measurements.

1. Introduction

In near-field planar scanning, we know that if the receiving pattern of the probe has a null in a given direction, then the far-field pattern of the test antenna cannot be determined reliably in that direction [1]. That is, the probe must be sensitive to plane-wave modes of interest. On the other hand, in near-field spherical scanning, there is no direct relationship between the probe and the test antenna patterns in a given direction. Nevertheless, we argue that the probe must be sensitive to all spherical-wave modes needed to represent the radiated fields.

This paper presents a small selection of results from a larger study of probe-sensitivity issues in external and internal spherical-scanning measurements. We calculate and discuss probe (modal) sensitivity as an aid in the choice of probes and measurement parameters (this is an expanded version of a paper presented at the 2012 Antenna Measurements Techniques Association Symposium [2]).

2. External Scanning

In external spherical scanning, we determine the radiated fields outside of the measurement sphere that are due to sources confined within the measurement sphere (see Figure 1). This is commonly called spherical scanning without the qualifier “external.” The theory presented here is a synopsis with little detail beyond that needed for understanding this paper. A complete discussion may be found in [3].

The far-field radiation of an antenna can be characterized by This formula embodies the linear relationship between the radiated electric field and the excitation . The transmission function may be expanded as where and are vector spherical harmonics [4, Chapter 16], which depend only on the direction , and the are (unknown) modal coefficients.

The antenna under test (AUT) is characterized by measurement with a probe that moves over a spherical surface of radius , enclosing the AUT. To account for polarization, two measurements are made for each probe location . These measurements correspond to probe orientations differing by a rotation of 90° about the probe axis. We follow common practice and use a “special symmetric” or “” probe. For such probes, the polarization measurements are the components of a transverse “measurement vector” that also may be expanded in spherical harmonics:

The relationship between the (known) and the is given by the probe-correction equations where The translated probe coefficients are basically the responses of the probe, located at , to each of the multipoles that compose the basis of vector spherical waves. Symbolically, where the operator denotes the probe and and represent magnetic and electric multipoles, respectively, that generate outgoing waves at infinity. For a special symmetric probe, unless .

We consider linearly polarized probes with symmetries that are actually satisfied by many practical probes. In this case is diagonal and where the probe sensitivity is defined as In the general case, appropriate sensitivities may be defined as the singular values of [5]. Of course, quantities corresponding to our definition of probe sensitivity are calculated, directly or indirectly, in any standard version of probe-corrected, near- to far-field transformation software.

When is small, is generally the ratio of two small numbers. As the signal falls towards the noise floor, the relative uncertainty in and thus can become extremely large. On the other hand, enhanced sensitivity to some modes is not necessarily beneficial. When the full dynamic range of the receiver is available, it is generally better to have uniform sensitivity over the modes of interest. The condition number is a good measure of merit; the optimum value is .

3. Internal Scanning

In internal spherical scanning, we determine the radiated fields within the measurement sphere that are due to sources located outside of the measurement sphere (see Figure 2). In the neighborhood of the coordinate origin (centered in the measurement sphere), where is the “transmitting function” of the sources. In principle, knowledge of allows compensation, say, of compact range measurements, for the effects of nonuniform illumination [68].

Equations (2)–(10) also apply to internal scanning, with the exception that (6) becomes where and represent magnetic and electric multipoles, respectively, that remain finite at the origin. This “small” change has a profound effect on the nature of probe correction in the interior versus exterior case.

4. Processing and Uncertainty

Data typically are collected on a uniform grid in and with sample increments chosen to satisfy the Nyquist sampling theorem In the NIST algorithm, the angular measurements are transformed to a Fourier representation by use of the fast Fourier transform (FFT). Orthogonality integral relations are then employed to project the Fourier representation onto the basis of spherical harmonics, producing the representation (3). Finally, probe effects are removed through deconvolution to yield the far-field pattern (2).

The FFT is unitary so that the root mean square (RMS) error in the Fourier representation is the same as the RMS error in the measured data. The projection operation also will not increase the RMS error; in fact, there will be a reduction if some of the error signal lies in the null space of the projection. For the probe deconvolution, assuming that the uncertainty in sensitivity is , we have (see (A.3)), where, for example, Thus, the use of a poor probe can lead to significantly expanded uncertainties.

We can also account for the fact that the sensitivities are not known precisely. With (See (A.5)) Here Equations (14) and (16) may be combined in quadrature to give an overall view of the effect of probe deconvolution on measurement uncertainty: Although illustrative and easy to derive, (18) gives a conservative estimate of uncertainty that can be refined.

NIST software calculates with double-precision accuracy to ensure that computational errors are negligible compared to measurement errors.

5. Examples

We consider a mode cut-off of . This is sufficient for the representation of radiated fields when . In the external case, is the radius of the minimum sphere of the test antenna. In the internal case, is the radius of the test zone. For practical reasons, the measurement radius is usually chosen to be or more wavelengths greater than . The radius with is just outside the sphere . The radius with is greater than or equal to twice .

Actual probes used in this study are shown in Figure 3. These all operate at Ku band, 12.4–18 GHz.

The plots are normalized so that the peak sensitivity in any figure has the value 1.

5.1. External Case

Ideal dipole probes provide a direct measurement of components of the electric and magnetic field. Although practical probes only approximate ideal probes at best, ideal probes are effectively assumed in instances when “no probe correction” is applied. Also, practical probes become increasingly ideal as is increased. Figures 46 show sensitivities for a “Huygens probe,” which is an ideal probe that consists of a crossed electric and magnetic dipole. This is a maximum-directivity probe of order with a directivity dB [9, Section  2.3.4]. Figure 4 plots as a function of for several values of . At any given radius, there is very little variation in sensitivity with . Otherwise, we observe the expected decrease in sensitivity as increases. Figures 5 and 6 show as a function of for and . When , and at , . The trend for conditioning to improve as increases is consistent with an asymptotic analysis of the sensitivity of linearly polarized probes [3, Appendix  C].

Figures 79 feature the NIST SN 330 probe with gain  dB [3, Appendix  B]. Figure 7 plots as a function of for several values of . Compared to the Huygens probe, there is considerable variation in sensitivity with for smaller values of . Figures 8 and 9 show as a function of for and 200. When , , and at , .

Figures 1012 show the NIST SN 1057 dual-port probe with gain  dB. Figure 10 plots as a function of for several values of . Figures 11 and 12 give as a function of for and 200. When , , and at , .

Figures 1315 feature the NIST SN 401 probe with gain  dB. This probe resembles SN 330, except that a flare has been added to increase the directivity. Figure 13 plots as a function of for several values of . Variation in sensitivity with for smaller values of is problematic. Figures 14 and 15 show as a function of for and . When , and at , . In order to obtain similar conditioning, this probe must be used at considerably larger values of than those for the lower directivity probes discussed here.

5.2. Internal Case

In the internal case, conditioning is significantly affected by the fact that radial functions (spherical Bessel functions) have zeros. Figure 16 plots as a function of for several values of , when the probe is an ideal electric dipole ( dB). The variation in sensitivity with is extreme and it seems unlikely that any choice of one or several values of would allow reliable determination of all of the modes. Figure 17 plots as a function of for . At this radius, .

Fortunately, the Huygens probe ( dB) is much better behaved, as illustrated in Figures 18 and 19. Figure 18 plots as a function of for several values of and indicates a tendency for conditioning to improve as increases. Figure 19 shows as a function of for . At this radius, .

Figures 20 and 21 feature the NIST SN 330 probe ( dB). Figure 20 plots as a function of for several values of . Again, conditioning appears to improve as measurement radius is increased. Figure 21 shows as a function of for , for which .

Figures 22 and 23 show the NIST SN 1057 dual-port probe ( dB). Figure 22 plots as a function of for several values of . Again, conditioning appears to improve as measurement radius is increased. Figure 23 shows as a function of for , for which .

Figures 24 and 25 feature the NIST SN 401 probe ( dB). Figure 24 plots as a function of for several values of and indicates a significant range of sensitivity with . Figure 25 shows as a function of for , for which . This is certainly unacceptable for many applications.

Figure 26 compares NIST SN 330 ( dB), SN 331 ( dB), and SN 401 ( dB) at . SN 331 is a version of SN 330 with a smaller aperture. With all things equal, SN 401 has better sensitivity for multipole indexes less than but is significantly less sensitive for larger values of . Because of its higher gain, however, the SN 401 must be used at lower transmitted power levels. Improving the signal-to-noise ratio by increasing the transmitted power will tend to compensate for the reduced sensitivity of the lower-gain probes when .

6. Conclusions

For any given probe, sensitivities generally become more uniform as the measurement radius is increased. More directive probes must be used at larger measurement radii than less directive probes if the same condition number is desired.

The topic of probe sensitivity in spherical scanning seems not to have received much attention to date; yet, sensitivity can have a very significant impact on measurement accuracy. Our results are based on a limited number of examples; however, sensitivity information is readily available to anyone who processes spherical-scanning data. We strongly encourage metrologists to explore probe-sensitivity issues before making near-field antenna measurements. Optimization of sensitivity should be a consideration in the design of new probes.

Appendix

Partial Analysis of Uncertainty

From (8) where we are using a compact notation.

When , Therefore,

When , Therefore,

Disclosure

This research is US government work not protected by US copyright.

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.