Research Article
Optical Coupling Structures of Fiber-Optic Mach-Zehnder Interferometers Using CO2 Laser Irradiation
Table 4
Influence of the fluidic channel shape.
| Length (mm) |
Groove fluidic channel chip |
Linear fluidic channel chip | Slope (nm/RIU) | -square | Slope (nm/RIU) | -square |
| 10 | 17.3 | 0.98856 | 30.4 | 0.96057 | 20 | 12.2 | 0.99964 | 7.5 | 0.95356 | 30 | 19.5 | 0.97627 | 20.8 | 0.97674 | 40 | 54.4 | 0.97812 | 45.0 | 0.92771 | 50 | 38.4 | 0.97728 | 20.8 | 0.97674 |
|
|