Research Article

An Efficient Full-Wave Electromagnetic Analysis for Capacitive Body-Coupled Communication

Table 2

Comparison of specific coupler/body positions in Figures 7(b) and 7(d) for higher propagation loss.

Coupler/body position 1 Coupler/body position 2 Comparison between positions 1 and 2 for higher propagation loss

Arm position a (102 cm) Maximum propagation loss for arm positions in Figure 7(b)
Arm position f (135 cm) Arm position a (102 cm) Arm position a
Arm position d (53 cm) Arm position e (53 cm) Arm position d
Arm position c (116 cm) Arm position b (116 cm) Arm position b
Arm position c (116 cm) Arm position d (53 cm) Arm position d
Body position c (155 cm) Body position a (83 cm) Body position a
Body position c (155 cm) Body position b (121 cm) Body position b