Research Article
Electromagnetic Interference between Cranes and Broadcasting Antennas
Table 1
Induced voltages in case A.
| Voltage (V) | (kHz) | , | /2, | /2, /2 |
| 500 | 25.74 | 48.61 | 41.20 | 550 | 33.85 | 70.55 | 61.65 | 600 | 47.77 | 110.66 | 99.10 | 650 | 78.30 | 203.10 | 185.60 | 700 | 196.40 | 574.84 | 533.95 | 720 | 346.53 | 1067.93 | 997.05 | 726 | 370.75 | 1159.83 | 1085.61 | 727 | 370.34 | 1161.98 | 1087.43 | 728 | 368.51 | 1159.19 | 1085.32 | 735 | 325.62 | 1043.23 | 1069.28 | 750 | 207.44 | 691.59 | 978.15 | 800 | 76.63 | 294.23 | 650.84 | 850 | 44.39 | 198.67 | 512.33 | 900 | 29.95 | 158.59 | 421.28 | 1000 | 16.15 | 125.72 | 279.76 |
|
|