Effective attenuation constant for different types of buildings.
| Buildings | Type of external walls | Building thickness (m) | Average transmission loss (dB) | Average value of (dB/m) | Standard deviation of (dB/m) |
| Residential buildings Type A | | | | | | Building 3 | Bricks and glass windows | 56.46 | 46 | 1.16 | 0.22 | Building 5 | Bricks and glass windows | 32.30 | 29 | 1.06 | 0.15 | Residential buildings Type B | | | | | | Building 4 | Brick walls coated with ceramic, balconies, doors, and glass windows | 68.64 | 35 | 1.88 | 0.24 | Building 6 | Brick walls coated with ceramic, balconies, doors, and glass windows | 46.93 | 31 | 1.46 | 0.22 | University gymnasium | | | | | | Building 2 | Reinforced concrete walls and brick and cast walls for ventilation | 45.51 | 37 | 1.17 | 0.10 | Office buildings | | | | | | Building 1 | Bricks, windows, and wooden doors | 61.54 | 21 | 2.71 | 0.28 | Building 9 | Bricks and wood windows | 25.44 | 13 | 1.80 | 0.40 | Research laboratory | | | | | | Building 7 | Bricks and glass windows | 39.04 | 37 | 0.95 | 0.20 | Building 8 | Bricks and glass windows | 30.66 | 28 | 0.98 | 0.26 | Building 10 | Bricks and glass windows | 29.86 | 20 | 1.30 | 0.41 |
|
|