Table 1
Description of three test cases with deterministic and random parameters (see Figures
1 and
2).
| Test case # | Deterministic parameters | Random parameters | RV1 | RV2 | RV3 |
| () | Burial depth Electrode diameter Soil permittivity, permeability Equivalent source excitation | Soil conductivity, uniformly distributed between 1 and 10 mS/m | Electrode length, uniformly distributed between 45 and 55 m | — |
| () | Burial depth Electrode diameter, length Soil permittivity, permeability, conductivity | Lightning front times, uniformly distributed between 0.4 and 4 s | Lightning time-to-half, uniformly distributed between 50 and 70 s | — |
| () | Electrode diameter Soil permittivity, permeability Plane wave source | Soil conductivity, uniformly distributed between 1 and 9 mS/m | Electrode length, uniformly distributed between 9.5 and 10.5 m | Burial depth, uniformly distributed between 2.5 and 5.5 m |
|
|