Research Article
Space-Time Adaptive Cancellation in Passive Radar Systems
Table 2
Measured filter performances.
| Filtering method | Target SINR [dB] | CA [dB] |
| Spatial (MVDR) | 10.37 | 22.7 | Temporal (Wiener-SMI) | 43.6 | 36.9 | Spatial and temporal (MVDR & Wiener-SMI) | 26.37 | 34.1 | STAC before spatial and temporal (MVDR & Wiener-SMI) | 51.8 | 44.6 |
|
|