Research Article

Integrated Miniature Multiband Antenna Designed for WWD and SAR Assessment for Human Exposure

Table 5

Maximum SAR results of the antenna mounted on wrist configuration.

Distanced = 1 mmd = 2 mmd = 4 mmd = 7 mm
Frequency (MHz)TissueInput power (W)10 g SAR (W/kg)10 g SAR (W/kg)10 g SAR (W/kg)10 g SAR (W/kg)

2300Skin0.1252.0610.6570.6210.324
Fat0.1252.070.6660.630.333
Muscle0.1251.1250.5850.5490.189
Bone0.1250.3960.2430.2160.126

2400Skin0.1252.0790.6120.5580.432
Fat0.1252.0880.6210.5670.441
Muscle0.1251.170.5220.4590.396
Bone0.1250.2880.2160.1890.135

2600Skin0.1252.3490.810.6120.378
Fat0.1252.3580.8190.6210.387
Muscle0.1251.890.7470.4860.369
Bone0.1250.3240.2610.2250.126

3500Skin0.1252.9791.9621.7821.341
Fat0.1252.9881.9711.7911.35
Muscle0.1251.9531.8451.3771.188
Bone0.1250.5220.5040.450.36

5200Skin0.1253.2943.3482.5111.674
Fat0.1253.3033.3572.521.683
Muscle0.1252.5923.0512.1151.44
Bone0.1250.360.4591.9440.27

5800Skin0.1253.153.0331.9530.774
Fat0.1253.1593.0421.5120.783
Muscle0.1252.5382.6191.3770.693
Bone0.1250.2430.3150.2430.153