Research Article
A Dual-Band Wearable Conformal Antenna Based on Artificial Magnetic Conductor
Table 2
Comparison of the proposed antenna with other antennas reported in the literature.
| Ref. | Dimensions (mm2) | Number of unit cell | Freq. (GHz) | SAR value 1 g (W/kg) | Distance from body (mm) | Gain (dBi) |
| [9] | 72 × 72 | 3 × 3 | 2.45/5.8 | 2.48/3.33 | — | 5.2/7.7 | [10] | 86 × 86 | 4 × 4 | 3.5/5.8 | 0.0683/0.333 | 1 | 9.07/6.63 | [12] | 68 × 38 | 2 × 1 | 2.45 | 0.5 | 2 | 6.88 | [19] | 62 × 42 | 2 × 2 | 2.4 | 0.48 | 5 | 6.2 | [22] | 81 × 81 | 3 × 3 | 2.45 | 0.554 | 6 | 7.3 | [25] | 75.7 × 75.7 | 3 × 3 | 2.45 | 0.022 | 3 | 6.58 | This paper | 61.5 × 61.5 | 3 × 3 | 2.45/5.8 | 0.35/0.39 | 1 | 5.67/6.89 |
|
|