Research Article
Design and Measurement of a Vibrating Intrinsic Reverberation Chamber Working in Tuned Mode
Table 1
Comparison with traditional methods.
| Items | New method | Traditional method |
| Test system | Relatively complex | Simple | Statistical uniformity of spatial electric field | Easy access | Not easy to obtain, and the deformation amplitude and other parameters need to be adjusted many times | Working mode | Mode-tuned | Mode-stirred | Application range | Suitable for EMI testing of all types of electronic equipment | Only suitable for EMI test of energy sensitive electronic equipment |
|
|