Research Article
Phase Segmentation Methods for an Automatic Surgical Workflow Analysis
Table 7
Maximum average accuracy of all methods with
ranging from 10 to 100 and
ranging from 10 to 400.
| Method | Max average accuracy | | |
| FrameDiff_GridBlock_Top | 82.7% | 80 | — | FrameDiff_GridBlock_means | 84.4% | 20 | 230 | MultiCue_GridBlock_Top | 61.4% | 80 | — | MultiCue_GridBlock_means | 63.8% | 30 | 270 | FrameDiff_GridIntersect_Top | 81.1% | 100 | — | FrameDiff_GridIntersect_means | 83.2% | 20 | 260 | MultiCue_GridIntersect_Top | 52.3% | 70 | — | MultiCue_GridIntersect_means | 59.5% | 20 | 250 |
|
|