Research Article

Biomechanical Performances of Networked Polyethylene Glycol Diacrylate: Effect of Photoinitiator Concentration, Temperature, and Incubation Time

Table 1

Statistical parameters determined from the tensile tests of different kinds of PEGDA samples with nutrient conduit networks.

Test conditionsABCDEFGH

Failure stress
 Number of samples46366364
 Average49.3036.1740.4529.6862.9547.6450.3539.12
 St. dev.4.242.402.303.375.633.033.901.75
values
 Temperature effect0.007 (AB)0.004 (CD)0.003 (EF)0.001 (GH)
 Incubation time effect0.031 (AC)0.007 (BD)0.003 (EG)0.039 (FH)
 Photoinitiator concentration effect0.005 (AE)0.017 (BF)0.006 (CG)0.001 (DH)

PEGDA samples with nutrient conduit networks are represented by letters A to H, where samples A have photoinitiator concentration = 0.2%, test temperature = 23°C, and incubation time = 0 days, samples B have photoinitiator concentration = 0.2%, test temperature = 37°C, and incubation time = 0 days, samples C have photoinitiator concentration = 0.2%, test temperature = 23°C, and incubation time = 7 days, samples D have photoinitiator concentration = 0.2%, test temperature = 37°C, and incubation time = 7 days, samples E have photoinitiator concentration = 0.6%, test temperature = 23°C, and incubation time = 0 days, samples F have photoinitiator concentration = 0.6%, test temperature = 37°C, and incubation time = 0 days, samples G have photoinitiator concentration = 0.6%, test temperature = 23°C, and incubation time = 7 days, and samples H have photoinitiator concentration = 0.6%, test temperature = 37°C, and incubation time = 7 days.
values from the -tests of failure stresses of two groups of specimen are represented by ( ).