Research Article

Electrochemical Estimation of the Corrosion Rate of Magnesium/Aluminium Alloys

Table 2

Comparison between direct mass losses and the corresponding electrochemical estimates.

MaterialTimeDirectly measured mass losses (mg/cm2)Electrochemical estimates (mg/cm2)Ratio

1 h13.041.379.52
Mg3 h39.095.147.61
6 h78.1816.004.89

1 d5.523.361.64
AZ317 d38.623.911.61
10 d55.434.841.59

1 d0.0740.190.39
AZ807 d0.521.300.40
10 d0.741.850.40

1 d0.0881.110.079
AZ91D7 d0.627.640.081
10 d0.8910.820.082