Research Article
Experimental Study on the Influence of AC Stray Current on the Cathodic Protection of Buried Pipe
Table 1
The pipe-soil potential under different coating defect areas.
| The defect area (mm2) | The maximum value of the moment interference (V) | The measuring protection potential without interference (V) | The real protection potential without interference (V) | The measuring protection potential with interference (V) | The real protection potential with interference (V) |
| 50 | −1.523 | −1.000 | −0.948 | −1.034 | −0.857 | 100 | −1.282 | −1.000 | −0.955 | −1.031 | −0.842 | 200 | −1.354 | −0.998 | −0.951 | −1.030 | −0.847 | 300 | −1.302 | −0.997 | −0.956 | −1.034 | −0.795 | 400 | −1.455 | −0.992 | −0.946 | −1.020 | −0.812 | 625 | −1.298 | −0.988 | −0.952 | −1.020 | −0.834 |
|
|