Research Article

Study on the Electrochemical Performance of Sacrificial Anode Interfered by DC Stray Current

Table 4

The corrosion electrochemical parameters of the anode at different ambient temperature.

Experiment days
(d)
Ambient temperature (V)Cathodic slopeAnodic
slope
Polarization resistance (Ωcm2)Corrosion current
density
(μA/mm2)

010°C-5.2344.8022.2081.85
room-
temperature
-5.1314.8342.1842.19
30°C-4.9544.1532.1772.31

210°C-4.7385.0273.6881.47
room-
temperature
-5.0725.1063.6701.62
30°C-4.9315.2742.7811.63

410°C-5.2155.7234.6930.92
room-
temperature
-4.6415.08214.5990.98
30°C-4.6245.0233.5931.11

610°C-5.3785.6155.8570.76
room-
temperature
-4.7135.0265.7750.83
30°C-4.8584.9643.8761.02

810°C-5.4956.3626.4390.71
room-
temperature
-4.7245.1186.3790.71
30°C-4.5824.9544.0680.75