Research Article
Regression Analysis of Bond Parameters between Corroded Rebar and Concrete Based on Reported Test Data
Table 1
Parameters of pull-out specimens with plain rebar.
| References No. | Specimen size (mm) | Corrosion level (%) | (MPa) | (mm) | (mm) | No. of specimens | (mm) | Stirrup confinement | Reinforcement position | Test environment | Reinforcement type |
| [3] | 100×100×100 | 0.27–5.01 | 22.13 | 12 | 44 | 14 | 80 | No | Center | Accelerated corrosion | Plain bars | [4] | 100×100×100 | 0–5.01 | 22.13 | 12 | 44 | 14 | 80 | No | Center | Accelerated corrosion | Plain bars | [5] | 100×100×100 | 0–8 | 13.98, 21.1, 23.63 | 12 | 44 | 21 | 5d | No | Center | Accelerated corrosion | Plain bars | [6] | 150×150×150 | 0–11.9 | 39.8, 62.7, 73.4 | 12 | 69 | 52 | 60 | No | Center | Current density of 0.25mA/cm2 | Plain bars | [9] | 140×140×180 | 0–6.8 | 52.1 | 20 | 60 | 16 | 4d | Each half | Center | Direct current (0–2 A) | Plain bars | [16] | 140×140×180 | 0–6.77 | 54.15 | 20 | 60 | 16 | 4d | Each half | Center | Current density of 1.214mA/cm2 | Plain bars | [17] | 150×150×140 | 0–5.95 | 21.1 | 12 | 69 | 6 | 100 | No | Center | Accelerated corrosion | Plain bars | [18] | 150×150×150 | 0–10.41 | 24.81 | 18, 20, 22 | 30 | 17 | 100 | No | Side | Accelerated corrosion | Plain bars | [19] | 150×150×150 | 0–5.38 | 30 | 10 | 70 | 18 | 110 | No | Center | Current density of 0.3mA/cm2 | Plain bars | [20] | 100×100×150 | 0–12.2 | 33.5 | 16 | 42 | 5 | 50 | No | Center | Accelerated corrosion | Plain bars | [21] | 150×150×150 | 2.76–5.95 | 21.1 | 12 | 69 | 5 | 100 | No | Center | Accelerated corrosion | Plain bars |
|
|