Electrochemical parameters of polarization curves of X80 steel under different AC densities.

AC current density (A/m2)Time (d)Corrosion potential (V)Corrosion current density (μA/cm2)The ratio of anode to cathode Tafel slope

00-0.62448.994.528
5-0.91623.941.193
9-0.88140.320.824
300-0.66365.691.938
5-0.91225.950.917
9-0.89144.841.125
500-0.73093.111.482
5-0.87034.990.975
9-0.88240.200.947
1000-0.66166.832.910
5-0.86827.790.906
9-0.85237.920.880
2000-0.77386.630.992
5-0.82646.600.760
9-0.83243.150.737
3000-0.91490.380.876
5-0.79856.820.850
9-0.78561.890.842