Electrochemical parameters of polarization curves of X80 steel under different AC densities.
| AC current density (A/m2) | Time (d) | Corrosion potential (V) | Corrosion current density (μA/cm2) | The ratio of anode to cathode Tafel slope |
| 0 | 0 | -0.624 | 48.99 | 4.528 | 5 | -0.916 | 23.94 | 1.193 | 9 | -0.881 | 40.32 | 0.824 | 30 | 0 | -0.663 | 65.69 | 1.938 | 5 | -0.912 | 25.95 | 0.917 | 9 | -0.891 | 44.84 | 1.125 | 50 | 0 | -0.730 | 93.11 | 1.482 | 5 | -0.870 | 34.99 | 0.975 | 9 | -0.882 | 40.20 | 0.947 | 100 | 0 | -0.661 | 66.83 | 2.910 | 5 | -0.868 | 27.79 | 0.906 | 9 | -0.852 | 37.92 | 0.880 | 200 | 0 | -0.773 | 86.63 | 0.992 | 5 | -0.826 | 46.60 | 0.760 | 9 | -0.832 | 43.15 | 0.737 | 300 | 0 | -0.914 | 90.38 | 0.876 | 5 | -0.798 | 56.82 | 0.850 | 9 | -0.785 | 61.89 | 0.842 |
|
|