Research Article

Anticorrosive Effect of Halogenated Aniline Enaminoesters on Carbon Steel in HCl

Table 3

Electrochemical parameters obtained from LPR tests for halogenated aniline β-enaminoesters in 1.0 mol L-1 HCl medium in AISI 1020 carbon steel.

InhibitorConc. (mol L-1) (Ω cm2) (%)

Blank0.99951.79
F-EN1.0 × 10-50.99990.790.429543.2
1.0 × 10-40.998165.020.681068.6
1.0 × 10-30.997202.020.743674.4
1.0 × 10-20.997273.320.850585.0
Cl-EN1.0 × 10-50.99993.030.443344.3
1.0 × 10-40.999106.340.513051.4
1.0 × 10-30.998235.920.780578.0
1.0 × 10-20.998339.890.807681.8
Br-EN1.0 × 10-50.999117.160.557955.8
1.0 × 10-40.999126.120.589358.9
1.0 × 10-30.999142.750.637263.7
1.0 × 10-20.998236.110.780678.1
H-EN1.0 × 10-50.8594445.550.494449.1
1.0 × 10-40.8318772.960.508551.3
1.0 × 10-30.86421268.80.722472.1
1.0 × 10-20.83832467.60.808780.8