Research Article

Anticorrosive Effect of Halogenated Aniline Enaminoesters on Carbon Steel in HCl

Table 8

Values of parameters obtained from linearized Langmuir adsorption isotherm for the inhibitors on AISI 1020 carbon steel in 1.0 mol L-1 HCl using the electronic impedance spectroscopic data.

InhibitorCorrelation coefficient ()Slope (L Mol-1) (kJ Mol-1)

F-EN0.999991.170.852.00 × 104-35.06
Cl-EN0.999961.190.841.16 × 104-33.69
Br-EN0.999741.250.806.83 × 103-32.36
H-EN0.999951.260.801.06 × 104-33.46