International Journal of Chemical Engineering / 2010 / Article / Tab 5

Research Article

Assessment of the Performance of Membranes Type Koch in Hartha Power Plant

Table 5

Total results in details for the theoretical properties of each element in arrays 1 and 2 using Saehane software.

ArrayEl. No.Feed Pressure barFeed m3/hPermeate m3/hRecoveryFeed TDS (ppm)Permeate TDS (ppm)

1115.513.91.20.093282.815.7
214.912.61.20.0933605.618.5
314.511.51.10.0963972.421.8
414.110.41.00.14392.525.8
513.79.31.00.1044877.130.8
613.48.40.90.1085440.037.0

2112.914.90.80.0536097.542.8
212.214.10.70.0516439.450.1
311.613.40.70.0486780.158.8
411.112.80.60.0447116.069.0
510.612.20.50.417443.281.1
610.211.70.40.0377757.995.6

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.