High-Added Value Materials Production from OMW: A Technical and Economical Optimization
Table 2
Equipment, building, and operational costs for an OMW treatment unit of 50,000 t/yr capacity. Calculations of the fixed cost, initial networking capital cost, and investment capital cost in Euros.
Equipment for capacity Q1 = 50,000 t OMW/yr
Euro
Purchase and establishment of basic equipment (UF and RO units, mechanical and electrical parts, etc.)
1,000,000
Auxiliary settlement, environmental protection system, and equipment maintenance department (lifetime: 10 years)
78,000
Substation (lifetime: 15 years)
30,000
Quality control laboratory equipment (lifetime: 10 years)
21,000
Transportation unit and equipment store (lifetime: 10 years)
46,000
2 loading machines, clarks (lifetime: 10 years)
30,000
5 vehicles for OMW collection—product shell (lifetime: 10 years)
105,000
Safety equipment clothing (lifetime: 2 years)
5,000
Office equipment, PC, and furniture (lifetime: 10 years)
30,000
Total purchase and installation cost, CE1
1,345,000
Buildings cost
Offices, laboratory, storage and building equipment
240,000
Fencing
5,000
Building site
100,000
Building total (depreciation in 25 years apart from building site)