Each event in the fault tree.

NameEvent description

TENo flow of the overhead product to the deethanizer
IE1Pump (P-103) failure
IE2Control loop (LIC 102) failure
BE2Pump motor failure
BE1Mechanical part failure in the pump
BE5Liquid-level sensor failure
BE3Controller (LIC 102) failure
BE4Control value (LV 102) failure