Optimization results of multigeneration system.
| | (K) | (—) | (kPa) | (—) | MC (—) | (K) | (K) | Exergy eff. (%) | Total cost rate ($/h) |
| | Exergy efficiency as objective function | Design | 1100 | 9 | 1000 | 0.8 | 0.6 | 1400 | 400 | 19.6 | 158.2 | Optimum | 1050 | 8.99 | 1125 | 0.54 | 0.1 | 1362 | 412 | 21.89 | 154.4 | Variation | −4.55 | −0.11 | 12.5 | −32.5 | −83.3 | −2.71 | 3 | 11.68 | −2.4 |
| | Total cost rate as objective function | Optimum | 1100 | 9 | 1125 | 0.44 | 0.3 | 1325 | 430 | 15.3 | 145.1 | Variation | 0 | 0 | 12.5 | −45 | −50 | −5.4 | 7.5 | −21.9 | −8.3 |
|
|