Research Article

Parametric Analysis of a High Temperature PEM Fuel Cell Based Microcogeneration System

Table 2

Validation of cogeneration system.

VariableHTPEMHTPEM [19]LTPEM [25]

Operating conditions
Current density (A/m2)300042002000
Operating temperature (K)423433347
Steam-carbon-ratio 33.5
Fuel stoichiometry 1.251.21
Air stoichiometry 22
System outputs
Power (W)100010004800
Cell voltage (V) 0.550.50.74
Fuel processor efficiency (LHV) 80.978
Electrical efficiency (LHV) 27.72644
Thermal efficiency (LHV) 51.75236
Cogeneration efficiency (LHV) 79.47880
Fuel typeNGNGHydrogen

Values based on HHV
Numerical data by authors
Numerical data of a HT-PEM system
Experimental data of a LT-PEM system.