Research Article

Experimental Investigation of the Effects of Helical Roof on the Performance of Stairmand High Efficiency Cyclone

Table 3

Calculated cost-effectiveness for standard roof and helical roof cyclones.

ParametersCyclone designs
SDHRDSDHRDSDHRD

Inlet velocity1013.517
Inlet PM load, kg sāˆ’13.034.095.15
Cost-effectiveness, Wh tonāˆ’1 PM28.424.449.038.875.160.8
Cost reduction by helical roof14.1%20.8%19.0%

Cyclone designs are SD for standard design and HRD for helical roof design.