Research Article

Modeling and Design of a Multistream Plate-Fin Heat Exchanger in the Air Separation Units by Pinch Technology

Table 12

Design data of case study.

StreamHP airLP airLPN2WN2LPO2

Type of streamHotHotColdColdCold
Supply temperature (°C)4217−173−148−173
Target temperature (°C)−140−14032232
Mass flow rate (kg/s)8.7519.87.611.865.9
Pressure drop (k·Pa)6080304625
Density (kg/m3)1.291.291.251.251.43
Viscosity (kg/m·s) 10−51.731.731.661.661.95
Heat capacity (J/kg·K)1005100510391039918
(k) (W/m·K)0.120.120.120.120.12